logo
Send Message
HK FY-MED TRADING CO., LIMITED
Email tina@fyendoscopy.com TEL: 853-68902598
Home > products > Endoscopy Processor >
CV-260 Endoscopy Processor With Automatic White Balance And Pre-Frozen Image Capture
  • CV-260 Endoscopy Processor With Automatic White Balance And Pre-Frozen Image Capture
  • CV-260 Endoscopy Processor With Automatic White Balance And Pre-Frozen Image Capture
  • CV-260 Endoscopy Processor With Automatic White Balance And Pre-Frozen Image Capture

CV-260 Endoscopy Processor With Automatic White Balance And Pre-Frozen Image Capture

Model Number CV-260
Product Details
Highlight: 

CV-260 Endoscopy Processor

,

Pre-Frozen Image Capture Endoscopy Processor

,

Automatic White Balance Endoscopy Processor

Product Description

CV-260 Endoscopy Processor With Automatic White Balance And Pre-Frozen Image Capture

 

 

CV-260 has HDTV output, adaptive IHb color enhancement, IHb value calculation, and pseudo-color display, structure enhancement, electronic zoom, real-time image color drift correction flash release, automatic aperture control, pre-frozen image capture, automatic white balance, and other features.

 

 

Parameters Of CV-260 Endoscopy Processor

 

 

  • Brand: Olympus

  • Type: Endoscopy System

  • Model: CV-260

  • Description: All medical equipment, new and used, is thoroughly inspected by our engineers to ensure complete functionality.

  • External Dimensions: 370*72*465 mm

  • Weight:9.2kg

  • Power consumption:150VA

  • Video signal output:HDTV,SDTV

  • Main functions:HDTV output, adaptive IHb color enhancement, IHb value calculation and pseudo-color display, structure enhancement, electronic zoom, color drift correction for live images flash release, automatic iris control, pre-freeze image capture, automatic white balance

     

 

 

Details Of CV-260 Endoscopy Processor

 

 

cv-260External dimensions: 370 x 72 x 465 mm ( W x H x D )
Weight: 9.2KG

 

 

 

 

Recommendations for Endoscopic Maintenance and Care

 

 

  • Do not place the endoscope together with other instruments and avoid touching other parts with the insertion part.
  • Wait until the endoscope angle returns to the 0-degree state before pulling out.
  • Since the insertion part is long, please be careful when cleaning and storing it, and be sure to confirm that it is not stuck beforehand.
  • When sterilizing EVIS endoscopes with ethylene oxide, remove the waterproof cap; when sterilizing other endoscopes with ethylene oxide, put on the ETO cap.
  • Wait until the endoscope angle returns to the 0-degree state, then pull out from the trocar needle and trocar.
  • When adjusting the angle of the insertion part, the angle should not be smaller than the range indicated in the instruction manual.
  • Please keep the sheath as straight as possible during operation.
  • Hold the insert gently and handle it carefully when taking it out.
  • Store the endoscopy equipment for sale in a dry and well-ventilated place at room temperature and in a clean condition.

 

 

The processor has a signal processing circuit that is provided with a digital signal processor. The digital processor generates a coarse video signal that is indirectly displayable on a video screen from image signals generated by a charge coupled device sensor .An auxiliary circuit has a correction circuit that generates another coarse video signal that is directly displayable on the video screen included for the following: (a) video endoscope (b) a camera for an endoscope.

 

 

CV-260 Endoscopy Processor With Automatic White Balance And Pre-Frozen Image Capture 0

 

 

CV-260 Endoscopy Processor With Automatic White Balance And Pre-Frozen Image Capture 1

Contact Us at Any Time

853-68902598
Rd Central HongKong
Send your inquiry directly to us