UHI-2 Endoscopy Processor Maximum Flow Volume Indicator Breath Detector
  • UHI-2 Endoscopy Processor Maximum Flow Volume Indicator Breath Detector
  • UHI-2 Endoscopy Processor Maximum Flow Volume Indicator Breath Detector
  • UHI-2 Endoscopy Processor Maximum Flow Volume Indicator Breath Detector

UHI-2 Endoscopy Processor Maximum Flow Volume Indicator Breath Detector

Model Number UHI-2
Product Details
Highlight: 

UHI-2 Endoscopy Processor

,

Breath Detector Endoscopy Processor

,

Maximum Flow Volume Indicator Endoscopy Processor

Product Description

UHI-2 Endoscopy Processor Maximum Flow Volume Indicator Breath Detector

1. Function Introduction:

 

 

 

The Olympus UHI-2 is used to inflate cavities in the body to provide surgeons with more space to work during surgery. Most inflators use carbon dioxide to inflate cavities because the gas is not flammable, is non-colored, and is soluble in the body, which also greatly enhances the safety of the procedure. Inflators can be used for radiological imaging and endoscopic procedures.

 

 

2. Parameters Of UHI-2 Endoscopic Insufflator

 

 

  • Brand: Olympus

  • Type: Endoscopy System

  • Model: UHI-2

 

 

Dimensions of UHI-2 Endoscopic Insufflator:

 

 

  • Height: 6.5 in (16.5 cm)

  • Width: 11.6 in (29.5 cm)

  • Depth: 13.2 in (33.5 cm)

  • Weight: 22 lbs (10 kg)

 

 

 

3. Description of UHI-2 Endoscopic Insufflator:

 

 

The Olympus UHI-2 is a High-Flow insufflator with a built-in smoke evacuation system. It provides optimum abdominal conditions which allow for a more focused surgery. The UHI-2 has a large full panel display for quick status checks, a 3-step flow rate setting (Hi, Med, and Low) for fast setup, and an automatic overpressure release valve.

 

 

The Olympus UHI-2 is an endoscopic insufflator. Olympus insufflators are used to inflate a cavity within the body to give more workroom for the surgeons. Most insufflators use CO2 to inflate the cavity because it is non-flammable, colorless, and dissolves into the body. Insufflators can be used in radiological imaging as well as endoscopic procedures.

 

 

  • Maximum flow rate of 20 L/Min

  • Easy-to-Read displays

  • Excellent visibility, even during electrosurgery

  • 3 Main flow settings

  • Built-in smoke evacuation

  • Audible and visual pressure warnings

 

 

General of UHI-2 Endoscopic Insufflator:

 

 

 

  • Maximum Flow Rate: 20 L/Min

  • Bacterial Filter: Yes

  • Type (Configuration): Electronic

  • Display: Yes

  • Low-Pressure Warning: Yes

  • Flow Options:

    Low: 0.5 - 1.5 L/Min

    Medium: 1.5 - 9 L/Min

    High: 10 - 20 L/Min

  • Alert Type: Audible and Visual

  • Activation Press: Set Point + 5

  • Time Delay (Breath Detector): 0

  • Electronic Pressure Reduction: Yes

  • Insufflation Volume Indicator: Yes

  • Peritoneal Pressure Indicator: Yes

  • Gas Used: CO2

  • Other:

 

 