logo
Send Message
HK FY-MED TRADING CO., LIMITED
Email tina@fyendoscopy.com TEL: 853-68902598
Home > products > Endoscopy Processor >
2215 Laparo Pump Instrument Carts Pump Power In Good Condition
  • 2215 Laparo Pump Instrument Carts Pump Power In Good Condition
  • 2215 Laparo Pump Instrument Carts Pump Power In Good Condition
  • 2215 Laparo Pump Instrument Carts Pump Power In Good Condition

2215 Laparo Pump Instrument Carts Pump Power In Good Condition

Model Number 2215
Product Details
Highlight: 

Power Laparo Pump Instrument Carts

,

Good Condition Laparo Pump Instrument Carts

,

2215 Laparo Pump Instrument Carts

Product Description

2215 Laparo Pump Instrument Carts Pump Power In Good Condition

1. Function Introduction:

 
 

LAPARO PUMP 2215 -

Effective irrigation and suction in

within the framework of laparoscopic, minimally invasive

surgery.

 

 

- Easy handling due to simplicity of the instrument

- Optimal suction and lavage performance

- Compatibility with suction-

Compatible with suction and lavage instruments with integrated valves,

Particularly compatible with the modular suction/ irrigation arm of the R. Wolf

- High degree of safety through intelligent pressure control

- Simple fastening to flushing columns or

easy mounting on flushing stands or instrument carts

 

 

2. Parameters Of 2215 Laparo Pump

​​

 

  • Power supply connection 220-240 V AC, 50/60 Hz

  • Power consumption 55 VA

  • Dimensions (W x H x D) 143 x 317 x 170 mm

  • Maximum flushing capacity: 1.8 l/min, suction: 1.8 l/min

  • Maximum flushing pressure: 400 mmHg (±50 mmHg)

  • Vacuum, minimum -60 kPa (-10 kPa)

  • Weight approx. 6 kg

 
 

Recommendations for Endoscopic Maintenance and Care

 
 

  • Do not place the endoscope together with other instruments and avoid touching other parts with the insertion part.

  • Wait until the endoscope angle returns to the 0-degree state before pulling out.

  • Since the insertion part is long, please be careful when cleaning and storing it, and be sure to confirm that it is not stuck beforehand.

  • When sterilizing EVIS endoscopes with ethylene oxide, remove the waterproof cap; when sterilizing other endoscopes with ethylene oxide, put on the ETO cap.

  • Wait until the endoscope angle returns to the 0-degree state, then pull out from the trocar needle and trocar.

  • When adjusting the angle of the insertion part, the angle should not be smaller than the range indicated in the instruction manual.

  • Please keep the sheath as straight as possible during operation.

  • Hold the insert gently and handle it carefully when taking it out.

 
 
2215 Laparo Pump Instrument Carts Pump Power In Good Condition 0
 
 
2215 Laparo Pump Instrument Carts Pump Power In Good Condition 1

Contact Us at Any Time

853-68902598
Rd Central HongKong
Send your inquiry directly to us